- All products
- Power
- Relays
- Relay Module 2 Channel SSR 5V DC To 240 AC Solid State Low Level
- Relays
Features
- 2 independent relay channels
- 5V DC operating voltage
- Supports AC loads up to 240V and 2A per channel
- Optoelectronic isolation using an infrared LED and photo-Triac
- LED indicator for each channel
- No mechanical contacts, reducing wear and switching noise
- Fast switching operation
- Compatible with microcontrollers and digital control systems
Principle of Operation

When a control signal is applied to a channel, the internal infrared LED is activated. Its light triggers the photo-Triac, allowing AC current to flow through the connected load. The control circuit remains electrically isolated from the high-voltage output circuit.
The module uses a high-level trigger: 3.3–5.0V turns the relay ON, while 0–2.5V keeps it OFF.
Pinout
Input Connections
- DC+: Positive 5V DC supply.
- DC-: Ground connection.
- CH1: Control input for channel 1.
- CH2: Control input for channel 2.
Output Connections
- Connect one AC load to each channel.
- Each channel supports up to 240V AC and 2A.
- Follow the module's terminal markings when connecting the AC load.
Wiring
- Connect the module DC+ to the 5V supply.
- Connect DC- to the controller GND.
- Connect CH1 and CH2 to digital output pins of the controller.
- Connect the AC loads to the corresponding output terminals.
- Use HIGH to activate a channel and LOW to deactivate it.
Circuit

Library
No special library is required. The module can be controlled using standard Arduino digital output functions.
Code
const int relay1 = 2;
const int relay2 = 3;
void setup() {
pinMode(relay1, OUTPUT);
pinMode(relay2, OUTPUT);
// Relays OFF
digitalWrite(relay1, LOW);
digitalWrite(relay2, LOW);
}
void loop() {
// Relay 1 ON
digitalWrite(relay1, HIGH);
digitalWrite(relay2, LOW);
delay(1000);
// Relay 2 ON
digitalWrite(relay1, LOW);
digitalWrite(relay2, HIGH);
delay(1000);
// Both OFF
digitalWrite(relay1, LOW);
digitalWrite(relay2, LOW);
delay(1000);
}
Applications
- Home automation
- AC lighting control
- LED lighting systems
- Industrial automation
- Automatic test equipment
- Instrumentation systems
- Thermostat and heating control
- PLC-controlled AC loads
- Replacement for electromechanical relays where solid-state switching is preferred
Specifications
- Supply Voltage: 5V DC
- Number of Channels: 2
- Quiescent Current: 0mA
- Maximum Operating Current: 26.8mA
- Trigger Mode: High-level trigger
- Relay OFF: DC 0–2.5V
- Relay ON: DC 3.3–5.0V
- Load Voltage: 240V AC
- Load Current: 2A per channel
- Module Life: Up to 10 million switching operations
- Maximum Switching Frequency: 5KHz
Resources
Comparison
- SSRs use semiconductor and optoelectronic components instead of mechanical contacts.
- They provide fast switching with no mechanical contact wear, noise, or vibration.
- SSRs provide electrical isolation between the control and load circuits.
- This module is designed for AC loads and should not be used to switch DC loads.
- Electromechanical relays can support both AC and DC loads and may provide higher current capacity depending on the relay type.
Safety
This module can switch hazardous AC voltages. Disconnect power before wiring and use suitable insulation, enclosure, fusing, and wiring for the connected load. Do not exceed the 240V AC and 2A rating per channel.
Features
- 2 independent relay channels
- 5V DC operating voltage
- Supports AC loads up to 240V and 2A per channel
- Optoelectronic isolation using an infrared LED and photo-Triac
- LED indicator for each channel
- No mechanical contacts, reducing wear and switching noise
- Fast switching operation
- Compatible with microcontrollers and digital control systems
Principle of Operation

When a control signal is applied to a channel, the internal infrared LED is activated. Its light triggers the photo-Triac, allowing AC current to flow through the connected load. The control circuit remains electrically isolated from the high-voltage output circuit.
The module uses a high-level trigger: 3.3–5.0V turns the relay ON, while 0–2.5V keeps it OFF.
Pinout
Input Connections
- DC+: Positive 5V DC supply.
- DC-: Ground connection.
- CH1: Control input for channel 1.
- CH2: Control input for channel 2.
Output Connections
- Connect one AC load to each channel.
- Each channel supports up to 240V AC and 2A.
- Follow the module's terminal markings when connecting the AC load.
Wiring
- Connect the module DC+ to the 5V supply.
- Connect DC- to the controller GND.
- Connect CH1 and CH2 to digital output pins of the controller.
- Connect the AC loads to the corresponding output terminals.
- Use HIGH to activate a channel and LOW to deactivate it.
Circuit

Library
No special library is required. The module can be controlled using standard Arduino digital output functions.
Code
const int relay1 = 2;
const int relay2 = 3;
void setup() {
pinMode(relay1, OUTPUT);
pinMode(relay2, OUTPUT);
// Relays OFF
digitalWrite(relay1, LOW);
digitalWrite(relay2, LOW);
}
void loop() {
// Relay 1 ON
digitalWrite(relay1, HIGH);
digitalWrite(relay2, LOW);
delay(1000);
// Relay 2 ON
digitalWrite(relay1, LOW);
digitalWrite(relay2, HIGH);
delay(1000);
// Both OFF
digitalWrite(relay1, LOW);
digitalWrite(relay2, LOW);
delay(1000);
}Applications
- Home automation
- AC lighting control
- LED lighting systems
- Industrial automation
- Automatic test equipment
- Instrumentation systems
- Thermostat and heating control
- PLC-controlled AC loads
- Replacement for electromechanical relays where solid-state switching is preferred
Specifications
- Supply Voltage: 5V DC
- Number of Channels: 2
- Quiescent Current: 0mA
- Maximum Operating Current: 26.8mA
- Trigger Mode: High-level trigger
- Relay OFF: DC 0–2.5V
- Relay ON: DC 3.3–5.0V
- Load Voltage: 240V AC
- Load Current: 2A per channel
- Module Life: Up to 10 million switching operations
- Maximum Switching Frequency: 5KHz
Resources
Comparison
- SSRs use semiconductor and optoelectronic components instead of mechanical contacts.
- They provide fast switching with no mechanical contact wear, noise, or vibration.
- SSRs provide electrical isolation between the control and load circuits.
- This module is designed for AC loads and should not be used to switch DC loads.
- Electromechanical relays can support both AC and DC loads and may provide higher current capacity depending on the relay type.
Safety
This module can switch hazardous AC voltages. Disconnect power before wiring and use suitable insulation, enclosure, fusing, and wiring for the connected load. Do not exceed the 240V AC and 2A rating per channel.